Skip to main content
. 2015 Aug;28(8):989–998. doi: 10.1016/j.echo.2015.02.020

Table 2.

RV volumes and EF by 2D KBR versus CMRI

Measurement 2D KBR CMRI P
RV EDV (mL) 179 ± 66 176 ± 61 .16
RV ESV (mL) 107 ± 47 106 ± 47 .63
RV SV (mL) 73 ± 27 70 ± 26 .26
RV EF (%) 42 ± 10 41 ± 11 .66

EDV, End-diastolic volume; EF, ejection fraction; ESV, end-systolic volume; SV, stroke volume.

Data are expressed as mean ± SD; n = 27 (one patient excluded because of movement artifact during 2D KBR study).

Paired Student’s t test.