Skip to main content
. 2015 Aug 14;10(8):e0135811. doi: 10.1371/journal.pone.0135811

Table 1. Inhibition of nicotinic responses in CN21 and SH-SY5Y cells.

CN21 SH-SY5Y
Test compound n Log IC50 (M) Hill slope Log IC50 (M) Hill slope
MB775 1 DNC DNC - -
MB520 2 -2.06 ± 0.04 -0.75 ± 0.06 - -
MB408 3 -2.37 ± 0 26 -0.73 ± 0.06 - -
MB444 4 -2.51 ± 0.15 -0.72 ± 0.05 -3.27 ± 0.04 -1.81 ± 0.26
MB442 5 -2.56 ± 0.16 -0.60 ± 0.13 -4.01 ± 0.04 -2.10 ± 0.40
MB776 6 -3.50 ± 0.32 -0.50 ± 0.02 -4.54 ± 0.04 -1.88 ± 0.24
MB777 7 -4.81 ± 0.23 -0.72 ± 0.01 -4.43 ± 0.05 -1.80 ± 0.30
MB505 8 -5.30 ± 0.20 -0.99 ± 0.07 -4.76 ± 0.03 -1.74 ± 0.22
MB778 9 -5.94 ± 0.11 -1.56 ± 0.11 -5.38 ± 0.04 -1.66 ± 0.20
MB779 10 -6.05 ± 0.17 -1.34 ± 0.14 -5.78 ± 0.03 -1.28 ± 0.09

Log IC50 values for inhibition of nicotinic responses in CN21 and SH-SY5Y cells by the test compounds. Data show mean ± SEM. All values were obtained by best-fit of the Hill-equation as described in the methods section. DNC = fit did not converge.