Table 3. Echocardiographic parameters between the patient group and the control group.
Parameters | Patient group | Control group | p-value |
LVEDD (mm) | 48.07 ± 3.82 | 48.47 ± 3.95 | 0.986 |
LVESD (mm) | 29.8 ± 4.78 | 30.43 ± 4.22 | 0.140 |
IVS (mm) | 10.08 ± 1.33 | 9.90 ± 1.19 | 0.720 |
LVEF (%) | 68.01 ± 7.01 | 66.31 ± 6.59 | 0.762 |
RVEDD (mm) | 28.78 ± 3.15 | 28.47 ± 3.67 | 0.523 |
LA diameter (mm) | 36.35 ± 3.81 | 36.94 ± 3.08 | 0.710 |
RA diameter (mm) | 32.99 ± 4.93 | 31.31 ± 4.72 | 0.535 |
Tricuspid E (cm/s) | 55.8 ± 12.6 | 54.6 ± 8.3 | 0.888 |
Tricuspid A (cm/s) | 47 ± 13 | 41.7 ± 9.6 | 0.156 |
Tricuspid E/A ratio | 1.2 ± 0.4 | 1.3 ± 0.3 | 0.413 |
Tricuspid E DT (ms) | 190.2 ± 30.4 | 193.6 ± 19.5 | 0.365 |
LVEDD: left ventricular end-diastolic diameter, LVESD: left ventricular end-systolic diameter, IVS: interventricular septum, LVEF: left ventricular ejection fraction, RVEDD: right ventricular end-diastolic diameter, LA: left atrium, RA: right atrium, tricuspid E: peak velocity of early diastolic filling, tricuspid A: peak velocity of atrial diastolic filling, tricuspid E DT: deceleration time of early diastolic filling.