Skip to main content
. 2015 Jul 9;15(7):16557–16575. doi: 10.3390/s150716557

Table 3.

Measurement errors: normalized root mean squared error (NRMSE) (%).

Floor Vision Sensor
Artificial Target Natural Target
Base 0.39 0.60
1st 0.28 0.45
2nd 0.27 0.35
3rd 0.18 0.32