Table 1.

Summary of SAXS experiments

Data Collection
Beamline SSRL Beamline BL4-2
Defining slit size (mm) 0.3(H) × 0.3 (V)
Beam energy (keV) 11
Sample-detector distance (m) 1.7
Detector Rayonix MX225-HE
Pixel binning 8 × 8
Pixel size (μm) 292
Exposure time (s) 1
Images images taken for duration of run =∼700 images
Type of sample cell quartz capillary (diameter 1.5 mm)
Temperature (K) 283
Calibrant AgBe
Final q range (Å−1) 0.01 to 0.5

Data Analysis

Programs SASTOOL (47), PRIMUS (48)
Buffer 20 mM Tris, 50 mM NaCl, pH 7.5
Injected protein concentrations (mg/mL) see Table 2
Points used for Guinier analysis see Table 2
Guinier qRg limits see Table 2
Guinier Rg (Å) see Table 2
GNOM q range (Å−1) see Table 2
Dmax (Å) see Table 2
Rg (real) (Å) see Table 2
Rg (reciprocal) (Å) see Table 2

Modeling

Programs IMP (rrt_sample, foxs, multi_foxs), Pymol
Data plotting GNUPLOT