Skip to main content
. 2015 Aug 13;2015:581719. doi: 10.1155/2015/581719

Table 2.

Mean difference in the AS-OCT parameters in the two study groups at pre- and post-LPI.

Pre-LPI Post-LPI p-value (difference) p-value (difference, ratio)
NBG BG NBG BG
ACD (mm) 2.100 ± 0.211 2.110 ± 0.301 2.092 ± 0.208 2.113 ± 0.307 0.3624 0.4208
LV (mm) 0.982 ± 0.200 0.889 ± 0.245 1.071 ± 0.234 0.967 ± 0.266 0.1444 0.1511
IC (mm) 0.354 ± 0.077 0.320 ± 0.076 0.131 ± 0.059 0.104 ± 0.045 0.9582 0.2412
IA (mm2) 1.516 ± 0.268 1.588 ± 0.235 1.632 ± 0.297 1.674 ± 0.246 0.9107 0.8769
ARA750 (mm2) 0.154 ± 0.081 0.116 ± 0.079 0.193 ± 0.070 0.149 ± 0.088 0.8848 0.1536
TISA750 (mm2) 0.122 ± 0.063 0.099 ± 0.067 0.164 ± 0.058 0.132 ± 0.073 0.7420 0.0568
AOD750 (mm) 0.229 ± 0.083 0.239 ± 0.098 0.314 ± 0.102 0.284 ± 0.136 0.0584 0.2082
IT750 (mm) 0.359 ± 0.065 0.378 ± 0.082 0.369 ± 0.067 0.381 ± 0.066 0.5110 0.6178

A mixed-effects model was used to compare the pre-post AS-OCT parameter's mean difference and relative difference between the two groups, adjusted for age, gender, SE, PD and the difference of pre-post-PD.

Abbreviations: AS-OCT: anterior segment optical coherence tomography; BG: basal insertion group; NBG: nonbasal insertion group; ACD: anterior chamber depth; IT750: iris thickness from the scleral spur (at 750 m from the scleral spur); IA: cross-sectional area of the iris; IC: iris curvature; LV: lens vault; AOD750: angle opening distances (corneoscleral wall 750 m anterior to the scleral spur); ARA750: angle recess area formed by the AOD750; TISA750: trabecular-iris space area, trapezoidal area with the following boundaries: anteriorly, the AOD750; posteriorly, a line drawn from the scleral spur perpendicular to the plane of the inner sclera wall to the opposing iris; superiorly, the inner corneoscleral wall; and inferiorly, the iris surface; PD: pupillary distance.