Table 2.
Mean difference in the AS-OCT parameters in the two study groups at pre- and post-LPI.
| Pre-LPI | Post-LPI | p-value (difference) | p-value (difference, ratio) | |||
|---|---|---|---|---|---|---|
| NBG | BG | NBG | BG | |||
| ACD (mm) | 2.100 ± 0.211 | 2.110 ± 0.301 | 2.092 ± 0.208 | 2.113 ± 0.307 | 0.3624 | 0.4208 |
| LV (mm) | 0.982 ± 0.200 | 0.889 ± 0.245 | 1.071 ± 0.234 | 0.967 ± 0.266 | 0.1444 | 0.1511 |
| IC (mm) | 0.354 ± 0.077 | 0.320 ± 0.076 | 0.131 ± 0.059 | 0.104 ± 0.045 | 0.9582 | 0.2412 |
| IA (mm2) | 1.516 ± 0.268 | 1.588 ± 0.235 | 1.632 ± 0.297 | 1.674 ± 0.246 | 0.9107 | 0.8769 |
| ARA750 (mm2) | 0.154 ± 0.081 | 0.116 ± 0.079 | 0.193 ± 0.070 | 0.149 ± 0.088 | 0.8848 | 0.1536 |
| TISA750 (mm2) | 0.122 ± 0.063 | 0.099 ± 0.067 | 0.164 ± 0.058 | 0.132 ± 0.073 | 0.7420 | 0.0568 |
| AOD750 (mm) | 0.229 ± 0.083 | 0.239 ± 0.098 | 0.314 ± 0.102 | 0.284 ± 0.136 | 0.0584 | 0.2082 |
| IT750 (mm) | 0.359 ± 0.065 | 0.378 ± 0.082 | 0.369 ± 0.067 | 0.381 ± 0.066 | 0.5110 | 0.6178 |
∗A mixed-effects model was used to compare the pre-post AS-OCT parameter's mean difference and relative difference between the two groups, adjusted for age, gender, SE, PD and the difference of pre-post-PD.
Abbreviations: AS-OCT: anterior segment optical coherence tomography; BG: basal insertion group; NBG: nonbasal insertion group; ACD: anterior chamber depth; IT750: iris thickness from the scleral spur (at 750 m from the scleral spur); IA: cross-sectional area of the iris; IC: iris curvature; LV: lens vault; AOD750: angle opening distances (corneoscleral wall 750 m anterior to the scleral spur); ARA750: angle recess area formed by the AOD750; TISA750: trabecular-iris space area, trapezoidal area with the following boundaries: anteriorly, the AOD750; posteriorly, a line drawn from the scleral spur perpendicular to the plane of the inner sclera wall to the opposing iris; superiorly, the inner corneoscleral wall; and inferiorly, the iris surface; PD: pupillary distance.