TABLE III.

Task-Based Characterization of Particulate Matter for Company A

Task Total Dust (mg/m3) MMAD, μm (GSD) Respirable Mass Fraction (%)
Cutting roof tiles in a roof valley 100 9 (2.4) 17
Cutting roof tiles to be used on a roof turret 107 9 (2.3) 15
Blowing tile dust off roof with leaf blower 6 13 (2.7) 11