Comparison of central venous catheter-related bloodstream infections according to the insertion site

Insertion site Number of infections per 1000 catheter days OR (95 % CI) P value
Subclavian versus internal jugular 2.28 vs. 3.47 0.670 (0.354–1.271) 0.221
Subclavian versus femoral 2.28 vs. 0.61 1.185 (0.368–3.819) 0.776
Internal jugular versus femoral 3.47 vs. 0.61 1.767 (0.499–6.262) 0.378

OR odds ratio, CI confidence interval