Table II.

Calculated rectal wall NTCPs for the planned and total delivered doses. A negative NTCP change means the NTCP calculated from the total delivered dose is less than that for the planned dose. NTCP Changes larger than +/−5% are shown in Bold. Changes of V30, V50, V70 and V75 between planned DVH and total delivered DVH are also shown. VD changes larger than +/− 10% are shown in Bold.

Balloon Patient Planned
NTCP
Delivered
NTCP
NTCP
change
Change of VD
V30 V50 V70 V75
A 1 16.6% 7.3% −9.4% −5% −4% −14% −16%
2 15.5% 17.9% 2.4% −2% 0 2% 3%
3 4.4% 6.5% 2.1% 9% 8% 3% 2%
4 24.0% 18.5% −5.5% −7% −6% −6% −9%
5 19.3% 8.8% −10.6% −11% −11% −15% −20%
B 6 14.0% 11.8% −2.3% −6% −2% −4% −5%
7 13.4% 8.0% −5.4% −20% −5% −10% −5%
8 17.8% 10.6% −7.2% −4% −8% −11% −12%
9 21.7% 12.9% −8.8% −5% −6% −9% −22%
10 16.5% 8.4% −8.1% −3% −9% −11% −13%