Skip to main content
. Author manuscript; available in PMC: 2016 Nov 1.
Published in final edited form as: Int J Cardiol. 2015 Jun 27;198:222–228. doi: 10.1016/j.ijcard.2015.06.093

Table 5.

Crossing strategies and equipment utilization.

Successful antegrade wiring (n=433)

Guidewire that crossed
 Pilot 200 36
 Fielder XT 19
 Fielder FC 5
 Confianza Pro 12 11
 Runthrough 8
 BMW 5
 Other 16

Successful Retrograde (n=273)

Collaterals used*
 Septal (%) 51
 Epicardial (%) 29
 Bypass graft – SVG (%) 17
 Bypass – LIMA (%) 2

Crossing techniques*
 Reverse CART (%) 67
 Retrograde true-to-true lumen (%) 19
 CART (%) 4
 Knuckle Wire (%) 6
 Kissing Wire (%) 2
 Just marker (%) 3

Successful antegrade dissection/re-entry (n=243)

Subintimal crossing (%) 74
True lumen crossing (%) 25

Successful dissection technique
 CrossBoss (%) 63
 Knuckle Wire (%) 28
 Antegrade wire entered subintimally (%) 9

Successful re-entry technique
 Stingray system (%) 79
 STAR (%) 11
 LAST (%) 3
 Other (%) 7
*

More than one collaterals or crossing techniques were used in some cases

CART, controlled antegrade and retrograde tracking and dissection; LAST, limited antegrade subintimal tracking; LIMA, lateral internal mammary artery; STAR, subintimal tracking and re-entry; SVG, saphenous vein graft.