Head motions
|
Displacements of each volume in Superior, Left, and Posterior directions. |
|
Rotations of each volume in degree (roll, pitch, yaw). |
CNR/SNR
|
CNR: the amplitude (I_max–I_min) image divided by the mean standard deviation of non-body background image. For each voxel, I_max and I_min are the 95% and the 5% percentiles of its intensity histogram across time, respectively. |
|
Histogram of CNR. |
|
Temporal SNR or tSNR, similar to Signal-to-Fluctuation Noise Ratio22 in Table 1. |
Registration
|
highres2standard: the high-resolution sMRI image registered to the MNI152 template space, with the WM/GM edge of the template shown in red. |
|
func2standard: the rfMRI images registered onto the 3*3*3 mm3 MNI152 template. |
|
func2highres: the rfMRI images registered onto the 1*1*1 mm3 T1 sMRI image. |
|
Segmentation, with GM, WM, and CSF colored and overlaid on the T1 image. |
Other Metrics
|
Regional homogeneity23. A measure to evaluate local signal homogeneity. |
|
Amplitude of low-frequency fluctuation or ALFF24. Measures the energy of low-frequency fluctuations in rfMRI data. |
|
Fractional ALFF26: Normalized ALFF. |