Relative quantity (RQ) values of selected miRNA as validated by real-time PCR in patients with endometriosis (n = 42) and control (n = 25).

Number miRNA Endometriosis
median (minimum–maximum values)
Control
median (minimum–maximum values)
p value Fold change difference between endometriosis and control by miRNA microarrays
1 miR-4454 0.34 (0.07–2.07) 0.41 (0.14–3.5) 0.34 1.51
2 miR-4714-5p 0.63 (0.05–9.9) 0.9 (0.01–4) 0.9 1.86
3 miR-5193 0.29 (0.04–11.3) 0.51 (0.04–22.9) 0.13 1.93
4 miR-4284 1.88 (0.1–10.3) 1.6 (0.2–15.7) 0.83 2.28
5 miR-5187-3p 0.28 (0.05–3.2) 0.20 (0.07–0.69) 0.051 1.41
6 miR-3680-5p 0.8 (0.07–31.6) 1.2 (0.06–11.2) 0.96 2.21
7 miR-3667-5p 0.68 (0.06–18.19) 1.8 (0.07–8.5) 0.63 2.3
8 miR-3152-5p 0.17 (0.03–1.4) 0.27 (0.002–2.8) 0.048 1.44
9 miR-23a-3p 1.22 (0.02–11.3) 1.17 (0.03–12.3) 0.48 1.55
10 miR-23b-3p 0.4 (0.06–1.7) 0.5 (0.1–2.2) 0.44 2.08
11 miR-30d-5p 0.22 (0.05–21) 0.42 (0.1–40) 0.05 1.37