TABLE 1.
Image Quality Ratings for 3612 Classifications by Image Modality and Standard Set
Quality | FSR [n (%)] |
DRRES [n (%)] |
DRILO2011-D [n (%)] |
---|---|---|---|
Good | 536 (44.5) | 792 (65.8) | 827 (68.7) |
Acceptable, no defects | 410 (34.1) | 332 (27.6) | 337 (28.0) |
Acceptable, some defects | 228 (18.9) | 74 (6.1) | 39 (3.2) |
Unacceptable | 15 (1.2) | 0 (0.0) | 1 (0.1) |
Missing/no indication | 15 (1.2) | 6 (0.5) | 0 (0.0) |
DRILO2011-D, digital radiograph interpreted using digitized ILO reference standards (2011-D); DRRES, digital radiograph interpreted using the “research” digitized standards; FSR, film-screen radiograph interpreted using 2000 ILO film-based reference standard; ILO, International Labour Organization.
Each chest radiograph from 172 miners was classified by seven National Institute for Occupational Safety and Health (NIOSH) B Readers for a total of 1204 classifications.