Skip to main content
. Author manuscript; available in PMC: 2016 Oct 1.
Published in final edited form as: Am J Cardiol. 2015 Jul 16;116(7):1082–1087. doi: 10.1016/j.amjcard.2015.06.032

Table 4.

Diagnostic value of a non-ischemic pattern on different cardiac magnetic resonance imaging sequences in the diagnosis of non-ischemic cardiomyopathy

Variable n Sensitivity (%) Specificity (%) Positive Predictive Value (%) Negative Predictive Value (%) Diagnostic Accuracy (%)
LGE* 36/83 68 89 89 68 77
LGE 17/83 34 97 94 53 61
Cine 53/83 79 56 70 67 69
LGE* or cine 59/83 87 50 69 75 71
LGE* and cine 30/83 60 94 93 64 75
LGE*, cine, or FPP 51/68 87 41 67 71 68
LGE*, cine, and FPP 22/68 51 93 91 59 69
Clinical algorithm 36/83 66 86 86 66 75
*

Absence of subendocardial and/or transmural late gadolinium enhancement (LGE)

Absence of subendocardial and/or transmural LGE, but presence of midwall and/or subepicardial LGE in ≥1 segments of the American Heart Association 17-segment model

Absence of regional wall motion abnormalities on cine imaging