Table 4.
Diagnostic value of a non-ischemic pattern on different cardiac magnetic resonance imaging sequences in the diagnosis of non-ischemic cardiomyopathy
Variable | n | Sensitivity (%) | Specificity (%) | Positive Predictive Value (%) | Negative Predictive Value (%) | Diagnostic Accuracy (%) |
---|---|---|---|---|---|---|
LGE* | 36/83 | 68 | 89 | 89 | 68 | 77 |
LGE† | 17/83 | 34 | 97 | 94 | 53 | 61 |
Cine‡ | 53/83 | 79 | 56 | 70 | 67 | 69 |
LGE* or cine | 59/83 | 87 | 50 | 69 | 75 | 71 |
LGE* and cine | 30/83 | 60 | 94 | 93 | 64 | 75 |
LGE*, cine, or FPP | 51/68 | 87 | 41 | 67 | 71 | 68 |
LGE*, cine, and FPP | 22/68 | 51 | 93 | 91 | 59 | 69 |
Clinical algorithm | 36/83 | 66 | 86 | 86 | 66 | 75 |
Absence of subendocardial and/or transmural late gadolinium enhancement (LGE)
Absence of subendocardial and/or transmural LGE, but presence of midwall and/or subepicardial LGE in ≥1 segments of the American Heart Association 17-segment model
Absence of regional wall motion abnormalities on cine imaging