Measure n Exposure Estimates (dBA)
Mean SD Bias Precision Accuracy ICC
Measured mean LEQi 89.6 3.4
TradeA (LEQ,TMi) 68 88.5 2.0 −1.1 3.8 4.0 0.14
Task-basedA (LEQ,TBi) 68 89.1 2.5 −0.5 3.1 3.1 0.48
SubjectiveB (LEQ,SRi)
 Noise frequency 68 91.7 1.0 2.5C 3.0 3.9 0.11
 Raise voice 68 91.6 0.5 2.6C 3.2 4.1 0.04
 Percent time in noise 68 91.8 1.0 2.2C 3.0 3.7 0.25

Note: n = three measurements per subject.

A

External noise levels developed from five sites.

B

Significant difference between estimated and measured levels (paired-sample t-test, p < 0.05).

C

External subjective noise levels developed from a single site.