Skip to main content
. 2015 Jan 21;52(10):6365–6374. doi: 10.1007/s13197-015-1739-x

Table 5.

The content of stevioside, glucose, fructose and sucrose (g/100 g) in blank and optimal samples during storage

Sugar Sample Temperature Time(days)
0 20 40 60
Sucrose blank refrigerator 9.333 ± 0.004a(A) 9.292 ± 0.003b(A) 9.227 ± 0.005cd(A) 9.195 ± 0.007d(A)
blank ambient 9.333 ± 0.004a(A) 8.853 ± 0.004b(B) 8.298 ± 0.005c(B) 7.754 ± 0.001d(B)
optimal refrigerator 5.832 ± 0.002a(B) 5.688 ± 0.009b(C) 5.586 ± 0.008c(C) 5.457 ± 0.001d(C)
optimal ambient 5.834 ± 0.007a(B) 5.208 ± 0.004b(D) 4.591 ± 0.015c(D) 3.980 ± 0.043d(D)
Glucose blank refrigerator 2.702 ± 0.002c(A) 2.718 ± 0.004c(B) 2.766 ± 0.004b(A) 2.804 ± 0.005a(D)
blank ambient 2.702 ± 0.002d(A) 2.855 ± 0.006c(A) 3.024 ± 0.020b(C) 3.205 ± 0.011a(B)
optimal refrigerator 2.460 ± 0.000d(B) 2.649 ± 0.011c(C) 2.771 ± 0.012b(C) 2.952 ± 0.002a(C)
optimal ambient 2.460 ± 0.000 d(B) 2.856 ± 0.007 c(A) 3.297 ± 0.007 b(A) 3.717 ± 0.009 a(A)
Fructose blank refrigerator 2.703 ± 0.004c(A) 2.732 ± 0.003bc(C) 2.782 ± 0.004ab(C) 2.822 ± 0.003a(D)
blank ambient 2.703 ± 0.004d(A) 3.388 ± 0.004c(A) 4.265 ± 0.078 b(A) 4.740 ± 0.000 a(B)
optimal refrigerator 2.440 ± 0.000d(B) 2.589 ± 0.005c(D) 2.756 ± 0.009b(C) 2.948 ± 0.002a(C)
optimal ambient 2.441 ± 0.000d(B) 3.308 ± 0.000c(B) 4.103 ± 0.017b(B) 4.874 ± 0.000 a(A)
Stevioside optimal refrigerator 0.061 ± 0.000a(A) 0.061 ± 0.000a(A) 0.059 ± 0.000b(A) 0.058 ± 0.000b(A)
optimal ambient 0.061 ± 0.000a(A) 0.056 ± 0.000b(B) 0.053 ± 0.000c(B) 0.050 ± 0.000d(B)

Values with different letters (capital letters in each column and minuscule letters in each row) represent significant difference at the confidence level of 99 %