Skip to main content
. 2015 Apr 18;174(10):1325–1332. doi: 10.1007/s00431-015-2538-0

Table 1.

Intubation success for all scenarios

Success rate Scenario A Scenario B Scenario C
MAC TruView MAC TruView MAC TruView
First (%) 115 (95.8 %) 120 (100 %) 69 (57.5 %) 120 (100 %) 55 (45.8 %) 118 (98.3 %)
Second (%) 120 (100 %) 120 (100 %) 90 (75 %) 120 (100 %) 78 (65.0 %) 120 (100 %)
Third (%) 120 (100 %) 120 (100 %) 98 (81.7 %) 120 (100 %) 82 (68.3 %) 120 (100 %)
Failed (%) 0 (0.0 %) 0 (0.0 %) 22 (18.3 %) 0 (0.0 %) 38 (31.7 %) 0 (0.0 %)

MAC Macintosh Laryngoscope, TruView TruView PCD Video-laryngoscope. Scenario A The chest compression scenario, Scenario B The chest compression scenario, Scenario C The chest compression with cervical stabilization scenario