Appendix Table 1.
Quality measures | All Colonoscopies (n=20,040) | Colonoscopies before Public Reporting (n=3,952) | Colonoscopies after Public Reporting (n=16,088) | P value |
---|---|---|---|---|
All Colonoscopies | ||||
Polyp removed during colonoscopy | 10,548 (52.6%) | 1,902 (48.1%) | 8,646 (53.7%) | <0.001 |
Adenoma removed during colonoscopy | 6,905 (34.5%) | 1,092 (27.6%) | 5,813 (36.1%) | <0.001 |
Advanced adenoma removed^ | 2,448 (12.2%) | 415 (10.5%) | 2,033 (12.6%) | <0.001 |
Large adenoma removed | 2,143 (10.7%) | 355 (9.0%) | 1,788 (11.1%) | <0.001 |
Villous, dysplastic changes, or carcinoma | 772 (3.9%) | 149 (3.8%) | 623 (3.9%) | 0.765 |
Adenoma to polyp ratio | 0.65 | 0.57 | 0.67 | <0.001 |
Limited to Screening Colonoscopies | ||||
Polyp removed during colonoscopy | 4,178 (57.0%) | 568 (52.5%) | 3,610 (57.7%) | 0.001 |
Adenoma removed during colonoscopy | 2,633 (35.9%) | 306 (28.3%) | 2,327 (37.2%) | <0.001 |
Advanced adenoma removed^ | 819 (11.2%) | 89 (8.2%) | 730 (11.7%) | 0.001 |
Large adenoma removed | 735 (10.0%) | 77 (7.1%) | 658 (10.5%) | 0.001 |
Villous, dysplastic changes, or carcinoma | 230 (3.1%) | 30 (2.8%) | 200 (3.2%) | 0.459 |
Adenoma to polyp ratio | 0.63 | 0.54 | 0.64 | <0.001 |
Other Quality Measures | ||||
Withdrawal time reported | 3,296 (16.4%) | 62 (1.6%) | 3,234 (20.1%) | <0.001 |
ASA classification of patient reported | 11,253 (56.2%) | 3 (0.1%) | 11,250 (69.9%) | <0.001 |
Informed consent documented | 20,037 (100%) | 3,950 (99.9%) | 16,087 (100%) | 0.041 |
Quality of colonoscopy prep reported | 20,040 (100%) | 3,952 (100%) | 16,088 (100%) | NS |
Adenoma size ≥ 10mm or pathology consistent with villous component or dysplastic changes