Table 1.
Site | δ, mm s−1 | ΔEQ, mm s−1 | Area, % | Relative area |
HydG57Fe | ||||
[4Fe–4S]+aux | 0.61*,† | 1.58* | 21.9 | 2*,† |
0.53* | 1.02* | 21.9 | 2*,† | |
Dangler Fe2+ | 1.19 | 3.47 | 11.0 | 1* |
[4Fe–4S]+RS | 0.58 | 1.27 | 19.4 | 1.8 |
0.51 | 1.00 | 19.4 | 1.8 | |
Other Fe | 0.72 | 2.85 | 6.4 | 0.6 |
HydGXN57Fe | ||||
[4Fe–4S]+aux | 0.61 | 1.58 | 40.1 | 2.0† |
0.53 | 1.02 | 40.1 | 2.0† | |
Dangler Fe2+ | 1.23 | 3.64 | 19.9 | 1 |
HydG57Fe-dangler | ||||
[4Fe–4S]+ | 0.68‡ | 1.68‡ | 28.1‡ | 0.8 |
0.45‡ | 1.20‡ | 16.9‡ | ||
Dangler Fe2+ | 1.22 | 3.64 | 55.0 | 1 |
Parameters were determined using the HydGXN57Fe sample and fixed during spectral fitting.
The intensities of the [Fe2+Fe2+] and [Fe2.5+Fe2.5+] doublets for each [4Fe–4S]+ cluster were fixed to be equal.
Because of the low intensity of the [4Fe–4S]+ cluster doublets in this sample, these fitting parameters are likely not accurate. Rather, they were used to obtain a close fit to the data to estimate the total intensity of the [4Fe–4S]+ cluster doublets relative to that of the dangler Fe2+ doublet.