Skip to main content
. 2015 Sep 22;15:127. doi: 10.1186/s12871-015-0105-x

Table 3.

Receiver operating characteristics (ROC) curve statistic for predicting changes > 15 % in SVI (fluid responders) at normal intra-abdominal pressure (A) and during intra-abdominal hypertension (B)

A
AUC 95 % CI p-value Best cut point Sensitivity Specificity
VT 6 ml/kg
SVV 70 % 49–92 0.111 3.5 75 % 56 %
PPV 79 % 61–98 0.022 4.5 75 % 81 %
VT 12 ml/kg
SVV 82 % 65–99 0.012 8.5 88 % 75 %
PPV 95 % 87–100 <0.001 9.5 75 % 94 %
VT 18 ml/kg
SVV 82 % 65–99 0.013 8.5 88 % 63 %
PPV 89 % 76–100 0.002 10 88 % 81 %
B
VT 6 ml/kg
SVV 64 % 33–95 0.445 5.5 50 % 63 %
PPV 67 % 35–99 0.35 5.5 75 % 38 %
VT 12 ml/kg
SVV 78 % 48–100 0.126 15 75 % 88 %
PPV 78 % 51–100 0.126 14.5 75 % 75 %
VT 18 ml/kg
SVV 84 % 61–100 0.062 18.5 50 % 75 %
PPV 73 % 44–100 0.203 24 75 % 63 %

(VT, Tidal Volume, SVV stroke volume variation, PPV Pulse pressure variation, AUC area under the curve)