Skip to main content
. 2015 Aug 21;16(8):20001–20019. doi: 10.3390/ijms160820001

Table 1.

Comparison of average hydrodynamic diameters measured using DLS and average core diameters determined using TEM for MNP-O, MNP-96, MNP-124, and MNP-142 distributions.

Sample DLS (nm) TEM (nm)
MNP-O 137.21 ± 20.8 75.4 ± 47.7
MNP-96 96.3 ± 9.0 62.6 ± 27.2
MNP-124 123.6 ± 7.9 80.7 ± 45.1
MNP-142 141.5 ± 10.8 104.6 ± 62.3