Table 2.

Product-Release Test for islets before transplantation.

Test Test method Criteria
Purity DTZ staining is used for islet identity, which is visualized by qualified personnel ≥30%
Viability Fluorescent dye (FDA and PI) staining is used for islet viability, which is determined by qualified personnel ≥70%
Islet yield DTZ staining is used for islet identity and islet number is counted by qualified personnel First transplant: ≥5,000 IEQ/kg RBW
Second transplant: ≥10,000 IEQ/kg RBW
Transplant tissue volume Centrifuge and measure packed cell volume in conical tube ≤10 mL
Microbiological test Gram stain on 100 μL smear with microscopic examination by qualified personnel No intact organism observed
Endotoxin content QCL-1000 Chromogenic LAL Test Kit, Cat number 50-647U, (BioWhittaker, Inc.) ≤5 EU/kg body weight of the potential recipient
Glucose static incubation In vitro insulin release in 1.6 mM and 16.7 mM glucose. Expressed by SI ≥1.5

DTZ: dithizone.

FDA: fluorescein diacetate, for live cells.

PI: propidium iodide, for dead cells.

RBW: recipient body weight.

SI: stimulation index.