Skip to main content
. 2015 Feb 25;23(10):1384–1391. doi: 10.1038/ejhg.2015.1

Table 2. Balanced case.

      P (type I error) Max loss of power (%) SDDIFF
Scenario ρ σ1 LMM TS CTS TS CTS TS CTS
1 −0.14 0.003 0.044 0.045 0.044 0.48 0 0.05 0.006
2 0 0.003 0.047 0.045 0.047 0.40 0 0.17 0.006
3 0 0.03 0.059 0.058 0.059 0.23 0 0.03 0.015
4 −0.5 0.003 0.063 0.052 0.063 31 0 0.66 0.007
5 −0.9 0.003 0.053 0.054 0.053 91 0 1.38 0.007
6 0.5 0.003 0.061 0.052 0.061 27 0 0.72 0.007
7 0.9 0.003 0.053 0.062 0.053 67 0 1.19 0.007
8 −0.9 0.03 0.056 0.056 0.056 0.5 0.21 0.12 0.015

Comparison of probability of type I error, loss of power with respect to LMM and precision measured by SDDIFF of two-step and conditional two-step