Skip to main content
. 2015 Aug 28;11:194. doi: 10.1186/s12917-015-0466-x

Table 7.

Proposed epilepsy specific MRI protocol for a low field machine

Veterinary epilepsy-specific protocol for 0.2 T MRI
Slice thickness 4 mm or less
➢ T1W – 3 sequence orientations
   ● Sagittal enabling identification of the long axis of the hippocampus
   ● Dorsal, perpendicular to the long axis of the hippocampus
   ● Transverse, parallel to the long axis of the hippocampus
 ➢ T2W - 2 sequence orientations for hippocampal angulation
   ● Dorsal, perpendicular to the long axis of the hippocampus
   ● Transverse, parallel to the long axis of the hippocampus
➢ FLAIR 1–2 sequence orientations for hippocampal angulation
   ● Dorsal, perpendicular to the long axis of the hippocampus
   ● Transverse parallel to the long axis of the hippocampus (optional)
➢ T1W post paramagnetic contrast enhancement
   ● If indicated by other pathology / desired by clinician
   ● Number of sequences determined by pathology