Skip to main content
. 2015 Oct 6;15:131. doi: 10.1186/s12871-015-0115-8

Table 3.

Bispectral index and haemodynamic data in the two study groups

Variable Propofol + saline Propofol + remifentanil
(n = 32) [Mean % difference from baseline] (n = 26) [Mean % difference from baseline]
BIS Baseline 96 (3) 97 (2)
Before SLMA insertion*, ** 36 (12) [63 %] 53 (14) [45 %]
1 min after SLMA insertion*, ** 37 (15) [64 %] 51 (15) [47 %]
6 min after SLMA insertion*, ** 28 (9) [71 %] 42 (16) [57 %]
Systolic BP (mmHg) Baseline 125 (15) 131 (15)
Before SLMA insertion*, ** 108 (13) [14 %] 95 (15) [27 %]
1 min after SLMA insertion*, ** 111 (17) [11 %] 94 (15) [27 %]
6 min after SLMA insertion* 97 (14) [23 %] 92 (11) [29 %]
Diastolic BP (mmHg) Baseline 76 (10) 78 (12)
Before SLMA insertion*, ** 66 (11) [12 %] 54 (12) [29 %]
1 min after SLMA insertion*, ** 68 (11) [12 %] 56 (12) [29 %]
6 min after SLMA insertion* 56 (11) [26 %] 55 (9) [28 %]
Heart rate (bpm) Baseline 72 (18) 71 (10)
Before SLMA insertion*, ** 71 (8) [0.01 %] 58 (9) [18 %]
1 min after SLMA insertion*, ** 74 (12) [0,03 %] 58 (10) [18 %]
6 min after SLMA insertion*, ** 62 (10) [14 %] 54 (8) [24 %]

Data are expressed as mean (SD)

BIS bispectral index, BP blood pressure, SD standard deviation

*p < 0.05; significant difference from baseline (difference within the group)

**p < 0.05; significant difference between the propofol + saline and propofol + remifentanil groups by ANOVA with repeated measurements