Skip to main content
. 2015 Apr 1;2:15011. doi: 10.1038/hortres.2015.11

Table 1. Gradient elution profile for HPLC analysis.

Mobile phase (%(v/v)) Elution time (min)
0 10 20 30 31 35
A 9 10 15 20 9 9
B 91 90 85 80 91 91

Compositions of mobile phase A: 5:95 (v/v) mix of acetonitrile:double distilled water containing 0.05% (v/v) orthophosphoric acid and mobile phase B: a 50:50 (v/v) mix of acetonitrile:double distilled water containing 0.05% (v/v) orthophosphoric acid. The elution method was based on the method of Zhang et al. 38