Published in final edited form as: Invest Radiol. 2015 Nov;50(11):749–756. doi: 10.1097/RLI.0000000000000179

Table 2.

A: Overall image quality scores provided by two readers for each phase of enhancement and for each acquisition/reconstruction scheme. Scores in early and late arterial phases are highlighted in bold.
Overall Image
Quality
GRASP XD-GRASP BH VIBE
Phase of
Enhancement
Reader 1 Reader 2 Reader 1 Reader 2 Reader 1 Reader 2
Non-contrast 3.50 ± 0.6 3.75 ± 1.1 3.94 ± 0.4 4.1 ± 0.8 3.94 ± 0.6 4.13 ± 0.6
Early Arterial 3.31 ± 0.6 3.38 ± 0.9 4.3 ± 0.6 3.81 ± 0.8 3.88 ± 0.6 3.50 ± 1.0
Late Arterial 3.63 ± 0.6 2.88 ± 0.7 4.5 ± 0.6 3.56 ± 0.5 3.44 ± 0.6 2.94 ± 0.9
Portal Venous 3.75 ± 0.8 3.81 ± 0.9 4.44 ± 0.5 4.0 ± 0.5 4.38 ± 0.6 4.0 ± 0.7
B: P value for pair-wise comparison of overall image quality score between acquisitions for each phase of enhancement stratified by reader. Significant differences are highlighted in bold.
Comparison Reader Non-contrast Early Arterial Late Arterial Portal Venous
XD-GRASP versus GRASP 1 0.063 <0.001 0.001 0.002
XD-GRASP versus GRASP 2 0.031 0.016 0.002 0.508
XD-GRASP versus BH VIBE 1 1.000 0.183 0.001 1.000
XD-GRASP versus BH VIBE 2 1.000 0.391 0.039 1.000