Table 1.

Measurements obtained from images of the pressurized rat mesenteric lymphatic vessel. Measurements reflect values of interest from one vessel subjected to range of pressure differences.

Pressure input description Symbol (units) Input Parameter Values
Inlet (Pin) and outlet (Pout) Pin (cmH2O) 6 3 3 1
Pout (cmH2O) 1 1 4 6
Description Symbol (units) Measured Parameter Values
Maximum diameter of the sinus area Dmax (μm) 163 155 160 167
Height from the root to the commissural incissura measured in the axial direction Hc (μm) 246 243 237 232
Height from the root to the trailing edge Hte (μm) 134 144 120 134
Length from root to maximum diameter Hmd (μm) 228 216 218 194
Length of the total sinus region Hs (μm) 456 432 436 388
Diameter of the elliptic orifice do (μm) 71 66 closed closed
Diameter of root Dr (μm) 112 105 102 95
Sinus-to-root ratio STR (n/a) 1.46 1.48 1.57 1.76