Skip to main content
. 2015 Aug 29;48(Pt 5):1437–1450. doi: 10.1107/S1600576715013187

Table 1. Results for the global fit parameters A, Inline graphic and R obtained by fitting equations (36) and (41) to the correlation functions of nanocrystalline Co and Ni displayed in Fig. 14 .

  Co [equation (36)] Co [equation (41)] Ni [equation (36)] Ni [equation (41)]
A (pJ mInline graphic) 54.6 (6) 29.1 (6) 15.1 (1) 13.7 (4)
Inline graphic 13.4 (0) 4.0 (1) 5.6 (0) 0.5 (1)
R (nm) 10.2 (1) 8.2 (6) 9.9 (1) 13.0 (1)