Table 2. Angiographic and procedural characteristics.
Vascular access | TR (n = 59) | TF (n = 67) | P-value |
Baseline QCA | |||
Reference vessel diameter, mm | 2.88 ± 0.40 | 2.91 ± 0.45 | 0.704 |
Lesion length, mm | 21.8 ± 10.0 | 21.4 ± 10.1 | 0.787 |
Minimal luminal diameter, mm | 0.56 ± 0.25 | 0.56 ± 0.17 | 0.861 |
Diameter stenosis, % | 80.5 ± 5.78 | 80.8 ± 5.93 | 0.810 |
Post-procedural QCA | |||
Reference vessel diameter, mm | 2.91 ± 0.42 | 3.00 ± 0.42 | 0.261 |
Minimal luminal diameter, mm | 2.68 ± 0.40 | 2.68 ± 0.47 | 0.961 |
Diameter stenosis, % | 8.02 ± 5.25 | 10.2 ± 6.63 | 0.073 |
Guide catheter diameter (Fr) | |||
6 Fr | 35 (59%) | 7 (10%) | < 0.001 |
7 Fr | 18 (31%) | 52 (78%) | < 0.001 |
8 Fr | 6 (10%) | 8 (12%) | 0.975 |
Number of burr used | 1.25 ± 0.57 | 1.39 ± 0.57 | 0.235 |
1 burr | 47 (80%) | 40 (60%) | 0.026 |
2 burrs | 8 (14%) | 25 (37%) | 0.005 |
3 burrs | 4 (6%) | 2 (3%) | 0.562 |
Largest size of burr use | |||
1.25 mm | 30 (51%) | 26 (39%) | 0.240 |
1.5 mm | 23 (39%) | 13 (19%) | 0.026 |
1.75 mm | 6 (10%) | 26 (39%) | < 0.001 |
2.0 mm | 0 (0%) | 2 (3%) | 0.533 |
Mean of burr size, mm | 1.39 ± 0.16 | 1.53 ± 0.24 | 0.001 |
Stent implantation | 53 (90%) | 60 (90%) | 0.809 |
Bare metal stent | 2 (4%) | 5 (8%) | 0.544 |
Drug-eluting stent | 51 (96%) | 55 (92%) | 0.673 |
Stent diameter, mm | 3.0 ± 0.5 | 3.1 ± 0.3 | 0.812 |
Stent length, mm | 24 ± 19 | 26 ± 21 | 0.789 |
Procedural success rate | 57 (97%) | 66 (99%) | 0.911 |
Data are expressed as mean ± SD or n (%). TF: transfemoral; TR: transradial; QCA: quantitative angiographic analysis.