. 2015 Sep 1;9(9):TC01–TC06. doi: 10.7860/JCDR/2015/13021.6428

[Table/Fig-3]:

Extraocular pathologies-Sensitivity, Specificity & Accuracy - Ultrasound diagnosis

Pathology Number of patients Ultrasonographic diagnosis Sensitivity of UD Specificity of UD Accuracy of UD
Optic glioma 4 4 100.0 100.0 100.0
Optic meningioma 1 1 100.0 100.0 100.0
Haemangioma 5 4 75.9% 99.5 80.0
Pseudotumour 2 2 100.0 100.0 100.0
Graves’ ophthalmopathy 2 2 100.0 100.0 100.0
Myositis 1 1 100.0 100.0 100.0
Cysticercosis 7 7 100.0 100.0 100.0
Dermoid 4 4 100.0 100.0 100.0
Dacrocystocele 2 2 100.0 100.0 100.0
Mucocele 3 3 100.0 100.0 100.0
Lymphoma 3 2 62.5 99.5 66.7
Lacrimal pleomorphic adenoma 2 2 100.0 100.0 100.0
Mucormycosis 1 1 100.0 100.0 100.0
Chloroma 1 1 100.0 100.0 100.0
AV malformation 1 1 100.0 100.0 100.0
Sebaceous cell carcinoma 1 1 100.0 100.0 100.0
Lid abscess 1 1 100.0 100.0 100.0
Lacrimal sac carcinoma 1 1 100.0 100.0 100.0
Total 42 40 94.2% 99.2 95.2