Skip to main content
. Author manuscript; available in PMC: 2017 Mar 1.
Published in final edited form as: Magn Reson Med. 2015 Apr 17;75(3):1333–1340. doi: 10.1002/mrm.25562

Table 2.

NIRS-observed values of %HbO2 and [THb] at the pre-occlusion, end-occlusion, and peak post-occlusion time points. Also shown are the times at which the greatest magnitude of post-occlusion %HbO2 and [THb] responses occurred, the Δ%HbO2END and Δ%HbO2POST values, and the Δ[THb]END and Δ[THb]POST values. To reduce table size, %HbO2 and [THb] are replaced with the letter V in the table header; other aspects of the abbreviations are unchanged. Mean ± SE are given; n = 6. For the variables reflecting changes from baseline, the 95% CI is also given. None of these CI’s included the value zero, indicating statistically significant changes.

V= VPRE VEND VPOST tV, POST (s) ΔVEND ΔVPOST
%HbO2 70.5 ± 1.8 52.7 ± 4.1 78.1 ± 2.7 71.7 ± 15.2 −17.9 ± 4.6 [−29.6, −6.1] 7.6 ± 2.6 [0.9, 14.3]
[THb] (μm) 69.3 ± 14.8 64.9 ± 13.4 79.0 ± 18.3 54.3 ± 9.5 −4.4 ± 0.63 [−8.6, −0.2] 1.6 ± 3.7 [0.1, 19.3]