Skip to main content
. 2015 Oct 4;2015:684826. doi: 10.1155/2015/684826

Table 2.

Summary of reviewed publications with S53P4 bioactive glass as treatment for chronic osteomyelitis.

Reference Clinical indication Number of treated patients with S53P4 implants Application form Number of successful treatments Complications related to S53P4 implant Study design Follow-up period [months] Examinations during follow-up
Romanò et al. [29, 30] Chronic osteomyelitis 27 Granules (size not reported) 25 2 recurrences of infection (with 1 fracture) Retrospective single centre cohort study 21.8 (average, range: 12–36) Clinical and laboratory evaluation and radiographs

Lindfors et al. [31] Chronic osteomyelitis 11 Granules (0.5–0.8, 0.8–1.0, 1.0–2.0, and 2.0–3.15 mm) 10 1 recurrence due to improper filling of the cavity Retrospective multicentre cohort study 24 (average, range: 10–38) Clinical examinations and radiological evaluation

McAndrew et al. [32] Chronic osteomyelitis 3 Granules (size not reported) 3 None Retrospective single centre case study 17.3 (average, range: 14–21) Radiological, haematological, and biochemical examinations