Skip to main content
. 2015 Oct 19;5:226. doi: 10.3389/fonc.2015.00226

Table 4.

Results for parameter estimates of linear-quadratic dose–response model for simple exchanges, and relative biological effectiveness (RBE) factors for protons of different energies compared to acute or low dose or low dose-rate γ-rays.

Radiation type α (Gy−1) β (Gy−2) RBEγAcute RBEmax
γ-Rays acute 0.157 ± 0.013 0.092 ± 0.027
γ-Rays LD 0.09 ± 0.004
Proton, 5 MeV 0.132 ± 0.016 0.031 ± 0.057 0.84 ± 0.1 1.5 ± 0.18
Proton, 120 MeVa 0.121 ± 0.015 0.137 ± 0.036 0.77 ± 0.1 1.36 ± 0.17
Proton, 250 MeV 0.088 ± 0.009 0.064 ± 0.017 0.56 ± 0.06 1.0 ± 0.1
Proton, 800 MeV 0.116 ± 0.028 0.104 ± 0.049 0.73 ± 0.18 1.3 ± 0.31
Proton, 1000 MeV 0.159 ± 0.02 0.081 ± 0.023 1.01 ± 0.13 1.79 ± 0.23
Proton, 2000 MeV 0.132 ± 0.028 0.071 ± 0.058 0.84 ± 0.19 1.49 ± 0.31
Proton, 2500 MeV 0.119 ± 0.01 0.077 ± 0.015 0.76 ± 0.07 1.35 ± 0.11

a150 MeV proton beam with 5 cm polyethylene shielding leading to residual energy of 120 MeV.