Skip to main content
. 2015 Aug 26;101(20):1639–1645. doi: 10.1136/heartjnl-2015-307745

Table 3.

MRI analysis of postoperative EF, LV mass and infarct volume

Placebo (n=35) Elafin (n=34)
Change in EF (%) −0.62±6.2 −2.4±6.3
Change in LV mass (g) 1.2±3.8 2.0±3.8
Change in infarct volume (%)
Reduced volume 2.9 0
No change 82.9 79.4
Increased volume 14.3 20.6