Table 4.
Monitoring values of haemodynamic parameters for fluid responsiveness
| AUC ± Std. error P | Optimal cutoff sens | Spec | PPV | NPV | |||
|---|---|---|---|---|---|---|---|
| SV ≥ 5 % | |||||||
| Delta PP (mmHg) | 0.76 ± 0.09 | 0.003 | 4 | 68 | 88 | 87 | 70 |
| Delta MAP (mmHg) | 0.74 ± 0.09 | 0.006 | 6 | 58 | 88 | 85 | 64 |
| Delta rHb (AU) | 0.72 ± 0.09 | 0.015 | −0.7 | 44 | 93 | 68 | 73 |
| SV ≥ 10 % | |||||||
| Delta PP (mmHg) | 0.77 ± 0.09 | 0.004 | 6 | 73 | 90 | 85 | 82 |
| Delta MAP (mmHg) | 0.75 ± 0.09 | 0.006 | 6 | 73 | 90 | 85 | 82 |
| Delta µHbSO2 (%) | 0.73 ± 0.09 | 0.015 | 2 | 64 | 79 | 69 | 75 |
| Delta rHb (AU) | 0.71 ± 0.09 | 0.025 | 1.5 | 50 | 89 | 78 | 71 |
| Delta MFI (AU) | 0.69 ± 0.10 | 0.048 | 0 | 71 | 69 | 67 | 73 |
AUC area under the curve, Std. standard, Sens sensitivity, Spec specificity, PPV positive predictive value, NPV negative predictive value, PP pulse pressure, SV stroke volume, MAP mean arterial pressure, μHbSO 2 microvascular haemoglobin oxygen saturation, rHb relative haemoglobin concentration, MFI microvascular flow index