Technical requirements

Criterium Minimum requirement Additional recommendation by the DGK
12-lead ECG Permanent availability
Blood pressure measurement At each bed Non-invasive blood pressure monitoring in the waiting room, facilities for implementing invasive monitoring
TTE Available 24/7, response time <30 min Dedicated CPU machine
Rhythm monitoring At each bed
Resuscitation Dedicated facilities, including defibrillator
Transportation with ECG monitoring Permanently available (if necessary with equipment from the intensive care unit) CPU-dedicated devices
Transport ventilator Permanently available (if necessary with equipment from the intensive care unit) CPU-dedicated devices
Laboratory diagnostics 24-h availability; turn-around time 45–60 min POCT, turn-around time <20 min
Blood gas analysis Available; turn-around time <15 min Integration in the CPU
External pacemaker Permanently available (if necessary with equipment from the intensive care unit) CPU-dedicated devices
Exercise stress test, CT Available within three business days; an appointment must be given upon discharge Cooperation with external walk-in clinics

TTE transthoracic echocardiography, POCT Point-of-Care Testing, CT computed tomography