TABLE 1.

Initial Guess Values and Bounds for Parameters Used in the Optimization

Para k1 k2 k3 k4 k5 Smb rb rm Sbm A1 A2 A3 L1 L2 L3 tau
Initial 5 0.1 0.1 0.001 0.02 0.01 0.9 0.6 0.5 300 0.1 199.97 −5 −0.06 −1 0.1
Upper 6 1.0 1.0 0.005 1.0 1.0 1.0 0.6 1.0 500 2 500 0 0 0 0.5
Lower 0 0.0 0.0 0.0 0.0 0.0 0.9 0.0 0.4 0 0 0 −10 −1 −10 0