Table 2.
Dose vs exposure time to achieve a prescribed biologically weighted dose of 60 Gy in the tumour (T) and balloon adjacent tumour bed tissue (TB) and normal tissue (N), with 72 µg of californium mass
| Therapy 252Cf plus | Time (h) | Dose (Gy) (relative biological effectiveness) |
||||
|---|---|---|---|---|---|---|
| T |
TB |
I1 |
I2 |
Na |
||
| 0.25b | 2.15 | 2.65 | 6.85 | |||
| BNCTc | 1.0 | 60d | 6.5 | 1.6 | 0.5 | 2.4 |
| BNCTc HWB | 54.0 | e | 60 | 91.5 | 30.0 | 20.7 |
| BNCTc LWB | 68.2 | e | 60 | 126.8 | 19.3 | 23.0 |
BNCT, boron neutron capture therapy; Cf, californium-252 brachytherapy; HWB, balloon catheter filled with heavy water; LWD, balloon catheter filled with light water.
Higher dose at normal tissue at a relative distance referent to 1.65 cm depth (surface balloon) in case of HWB and LWB, and 5.85 cm right to Cf-BNCT.
Relative distance between the centre of the Cf source and the voxel position in which the dose was evaluated, in centimetres.
Boron concentrations of 52.5 µg g−1 in the tumour and infiltrations, and 15 µg g−1 in the adjacent normal tissue (concentration ratio of 1:3.5).
Value taken at a voxel near the surface of the californium-252 source placed at a non-resectable tumour represented on the model.
Resected tumour; volume filled with moderator balloon.