Skip to main content
. 2015 May 28;88(1051):20140829. doi: 10.1259/bjr.20140829

Table 2.

Dose vs exposure time to achieve a prescribed biologically weighted dose of 60 Gy in the tumour (T) and balloon adjacent tumour bed tissue (TB) and normal tissue (N), with 72 µg of californium mass

Therapy 252Cf plus Time (h) Dose (Gy) (relative biological effectiveness)
T
TB
I1
I2
Na
0.25b 2.15 2.65 6.85  
BNCTc 1.0 60d 6.5 1.6 0.5 2.4
BNCTc HWB 54.0 e 60 91.5 30.0 20.7
BNCTc LWB 68.2 e 60 126.8 19.3 23.0

BNCT, boron neutron capture therapy; Cf, californium-252 brachytherapy; HWB, balloon catheter filled with heavy water; LWD, balloon catheter filled with light water.

a

Higher dose at normal tissue at a relative distance referent to 1.65 cm depth (surface balloon) in case of HWB and LWB, and 5.85 cm right to Cf-BNCT.

b

Relative distance between the centre of the Cf source and the voxel position in which the dose was evaluated, in centimetres.

c

Boron concentrations of 52.5 µg g−1 in the tumour and infiltrations, and 15 µg g−1 in the adjacent normal tissue (concentration ratio of 1:3.5).

d

Value taken at a voxel near the surface of the californium-252 source placed at a non-resectable tumour represented on the model.

e

Resected tumour; volume filled with moderator balloon.