Different tunnel entrance and exit guide angle corresponding to the stress of four bend (Gas pipeline)

Location No entrance and exit guides Guide angle = 15° Guide angle = 30° Guide angle = 45° Guide angle = 60°
Bend 1 358.92 MPa 358.62 MPa 351.91 MPa 343.62 MPa 334.83 MPa
Bend 2 362.24 MPa 362.19 MPa 361.74 MPa 361.15 MPa 360.55 MPa
Bend 3 358.76 MPa 358.76 MPa 358.47 MPa 358.12 MPa 357.77 MPa
Bend 4 356.13 MPa 354.35 MPa 342.23 MPa 327.34 MPa 312.00 MPa