Skip to main content
. 2015 Oct 18;8(5):954–959. doi: 10.3980/j.issn.2222-3959.2015.05.18

Table 3. The measured values of IOP and Pentacam parameters.

Parameters Pre-SLT±SD Post-SLT±SD (1st month) Post-SLT±SD (3rd month) P1 P2 P3
IOP 25.9±4.4 18.4±3.5 17.4±3.5 <0.01a <0.01a 0.055
K1 43.0±1.7 42.9±1.7 42.9±1.6 0.438 0.504 0.836
K2 43.9±1.8 43.8±1.8 43.9±1.8 0.837 0.824 0.656
CCT 573.5±25.8 591.7±36.1 565.5±30.6 <0.01a 0.033 <0.01a
ACD 2.8±0.4 2.8±0.4 2.8±0.4 0.435 0.263 0.643
ACV 146.8±47.4 143.1±46.7 145.3±46.0 0.001a 0.195 0.368
ACA 33.3±6.2 33.7±4.6 33.4±5.2 0.243 0.986 0.277
PD 3.4±1.0 3.3±0.7 3.3±0.7 0.986 0.633 0.828

SD: Standard deviation; IOP: Intraocular pressure (mm Hg); K1: Horizontal keratometry (mm); K2: Vertical keratometry (mm); CCT: Central corneal thickness (µm); ACD: Anterior chamber depth (mm); ACV: Anterior chamber volume (mm3); ACA: Anterior chamber angle (degree); PD: Pupil diameter (mm). aP<0.05 (paired t-test for IOP and Wilcoxon signed-ranks test for K1, K2, CCT, ACD, ACV, ACA, and PD). 1Comparison pre-SLT and post-SLT (1st month); 2Comparison pre-SLT and post-SLT (3rd month); 3Comparison post-SLT (1st month) and post-SLT (3rd month).