Skip to main content
. 2015 Oct 21;2(10):150447. doi: 10.1098/rsos.150447

Table 2.

Parameters and data for mass and thermal transport.

symbol parameter units value source equation
Lp hydraulic permeability, capillary wall (m2 s) kg −1 10−10 [47] (2.2b)
LLFp(s/v) effective permeability, lymphatic vessels (mmHg h)−1 0.5 [47] (2.2c)
cinj inflow IONP concentration gr m−3 1425.9 [47]
d edge length of IONP m 1×10−8 [17]
m mass of IONP gr 8×10−18 [17]
Dv vascular diffusivity of IONPs m2 s−1 9.0687×10−11 [47] (2.2e)
Dt interstitial diffusivity of IONPs m2 s−1 1.2955×10−11 [47] (2.2e)
P vascular permeability of IONPs m s−1 2×10−6 [47] (2.2b)
ρ tissue density kg mm−3 1060×10−9 [17] (2.3a)
γ tissue-specific heat capacity J kg−1 K−1 3470 [17] (2.3a)
κ tissue thermal conductivity kg mm−1 K−1 0.51×10−3 [17] (2.3a)
βT heat exchange coefficient W mm−2 K−1 2×10−5 [17] (2.3b)
Tbl blood temperature K 273.15+37 [17] (2.3a)
SAR specific absorption rate of IONPs W kg−1 1×106 [17] (2.3b)
ϵ tumour tissue volume fraction 0.8 [61] (2.2e)