Table 2. Model parameters.

Parameter Value Note
kb0 0.00055nM −1 s −1 From Desai et al. 2015
k D 350s −1 From Walcott et al. 2012
k T 2μM −1 s −1 From Walcott et al. 2012
C 70 From Walcott 2013, adjusted for closer myosin spacing
ε, pCa 7 0.02 From fits
ε, pCa 6 0.06 From fits (see S1 Supplementary Material)
ε, pCa 5 0.4 From fits
σ F 0.22 (scaled intensity) Estimated from Desai et al. 2015 (see S1 Supplementary Material)
σ N 0.21–0.36 (scaled intensity) Estimated from Desai et al. 2015, see Table 1
e 450 fluorescent units/s Estimated from Desai et al. 2015 (see S1 Supplementary Material)
σ GFP 160 nm (2 pixels) From Desai et al. 2015

Note: scaled intensity, defined in the text, gives a single fluorescently-labeled myosin an intensity of 1.