Table 6.
Diagnostic sensitivity and specificity for nasal swab samples (n=133) tested by (a) “perfect match” M gene RRT PCR assay and (b) “H1‐118” RRT PCR assay.
| n=133 | VI or independent H1N1v identification | Total | ||
|---|---|---|---|---|
| + | − | |||
| (a) *“Perfect match” M gene RRT PCR | + | 28 | 5 | 33 |
| − | 0 | 100 | 100 | |
| Total | 28 | 105 | 133 | |
| (b) †“H1‐118” RRT PCR | + | 28 | 1 | 29 |
| − | 0 | 104 | 104 | |
| Total | 28 | 105 | 133 | |
Sensitivity for both assays: 28/28+0 = 100%
* Specificity: 100/5+100 = 95·2%
† Specificity: 104/1+104 = 99·1%