Skip to main content
. Author manuscript; available in PMC: 2016 Sep 1.
Published in final edited form as: J Micromech Microeng. 2015 Aug 21;25(9):094001. doi: 10.1088/0960-1317/25/9/094001

Figure 10.

Figure 10

(a) Flow profile generated by the ac electrokinetic mixer and the charge accumulation on the surface of the electrodes. (b) Schematic of the micromixer device and flow profile generation. (c) Laminar flow of two fluids in a microfluidic channel with (bottom) and without (top) the ac and dc voltage components applied. A clear enhancement of the stream mixing can be seen over small distances when the voltages are applied. These figures were adapted from [88] with permission. Copyright 2009 Royal Society of Chemistry.