Skip to main content
. 2015 Nov 4;16:137. doi: 10.1186/s12931-015-0298-z

Table 3.

Hemodynamic response to adaptive servoventilation in patients with pre-capillary pulmonary hypertension (n = 21)

Baseline Intervention Recovery p*
Systolic blood pressure (mmHg) 117 ± 18 111 ± 13 119 ± 16 0.087
Diastolic blood pressure (mmHg) 65 ± 14 65 ± 9 68 ± 11 0.971
Heart rate (min−1) 69 ± 10 63 ± 11 66 ± 10 <0.001
Right atrial pressure (mmHg) 11 ± 4 13 ± 4 11 ± 5 0.002
Mean pulmonary artery pressure (mmHg) 46 ± 13 42 ± 12 44 ± 11 0.003
Pulmonary arterial wedge pressure (mmHg) 10 ± 3 15 ± 4 11 ± 3 <0.001
Cardiac output (l/min) 4.1 ± 1.1 3.6 ± 1.2 4.2 ± 1.3 0.001
Cardiac index (L/min/m2) 2.2 ± 0.4 1.9 ± 0.4 2.2 ± 0.4 <0.001
Stroke volume (ml/min) 62 ± 20 59 ± 20 63 ± 20 0.15
Pulmonary vascular resistance (dyn · s · cm−5) 754 ± 367 711 ± 372 750 ± 395 0.20
Peripheral oxygen saturation (%) 93 ± 2 97 ± 4 93 ± 3 <0.001
Mixed venous oxygen saturation (%) 65 ± 6 68 ± 6 62 ± 10 0.022
Mixed venous pCO2 (mmHg) 41 ± 5 37 ± 6 39 ± 8 0.001

*Baseline versus intervention