Table 3. Comparison of the area under the ROC curve (AUC) of our model with their models.
Model | AUC | Standard deviation | P value | 95% confidence interval |
|
---|---|---|---|---|---|
Lower limit | Upper limit | ||||
Proposed model | 0.910 | 0.027 | − | 0.857 | 0.963 |
Our model without Cyfra21-1 | 0.812 | 0.025 | 0.008 | 0.763 | 0.861 |
Brock model | 0.878 | 0.021 | 0.350 | 0.837 | 0.929 |
PKUPH model | 0.833 | 0.026 | 0.040 | 0.782 | 0.884 |
Mayo model | 0.752 | 0.045 | 0.003 | 0.664 | 0.841 |
VA model | 0.730 | 0.047 | 0.001 | 0.638 | 0.822 |
ROC, receiver operating characteristic; AUC, area under the curve.