Skip to main content
. 2015 Oct 28;5(10):e009251. doi: 10.1136/bmjopen-2015-009251

TableĀ 3.

Test characteristics for the IMPACT rule for predicting in-hospital mortality

Test characteristic Estimate (95% CI)
Sensitivity, % 92.4 (90.7 to 93.8)
Specificity, % 33.2 (32.7 to 33.7)
PPV, % 4.6 (4.4 to 4.9)
NPV, % 99.2 (99.0 to 99.4)
AUC 0.74 (0.73 to 0.76)

AUC, area under the receiver operator characteristic curve; IMPACT, In-hospital Mortality for PulmonAry embolism using Claims daTa; NPV, negative predictive value; PPV, positive predictive value.