Skip to main content
. Author manuscript; available in PMC: 2016 Dec 1.
Published in final edited form as: Bone. 2015 Jul 26;81:300–305. doi: 10.1016/j.bone.2015.07.033

Table 1.

Results from mixed models comparing µCT to DTS and HRCT topography measurements at superior endplates. The symbol ∪ indicates that the depth measurements from AP and LM views were pooled before calculation of the distribution statistics. The symbol ā indicates that the distribution statistics from AP and LM views were averaged. For ease of comparison with DTS/HRCT averages, µCT averages are presented below each parameter in parentheses.

µCT.Av
(Av=3.83)
µCT.SD
(Av=1.21)
µCT.Sk
(Av=−0.60)
µCT.Ku
(Av=3.43)
DTS.AP Av 2.63 0.97 −0.08 0.51
R2Adj 0.34 0.32 0.52 0.31
Slope 0.612 0.747 0.179 0.246
psl <0.0001 <0.0001 <0.03 <0.004
Intercept 2.214 0.476 −0.576 3.293
pint <0.0001 <0.002 <0.0001 <0.0001

DTS.LM Av 2.79 0.95 −0.47 0.17
R2Adj 0.21 0.27 0.51 0.31
Slope 0.629 0.876 0.392 0.239
psl <0.0001 <0.0001 <0.0001 <0.002
Intercept 2.048 0.366 −0.396 3.336
pint <0.0001 <0.002 <0.0001 <0.0001

DTS.AP∪LM Av 2.71 1.05 −0.11 0.06
R2Adj 0.30 0.20 0.53
Slope 0.829 0.675 0.362
psl <0.0001 <0.0001 <0.0005 NS
Intercept 1.565 0.486 −0.553
pint <0.0001 <0.0004 <0.0001

DTS.APāLM Av 2.71 0.96 −0.28 0.34
R2Adj 0.30 0.31 0.50 0.30
Slope 0.815 0.929 0.441 0.422
psl <0.0001 <0.0001 <0.0001 <0.0001
Intercept 1.601 0.309 −0.465 3.252
pint <0.0001 <0.02 <0.0001 <0.0001

HRCT Av 2.89 0.88 −0.83 1.00
R2Adj 0.37 0.19 0.57 0.40
Slope 0.443 0.550 0.256 0.234
psl <0.0001 <0.0001 <0.004 <0.0009
Intercept 2.555 0.717 −0.373 3.151
pint <0.0001 <0.0001 <0.0003 <0.0001