Skip to main content
. 2015 Nov 10;10:226. doi: 10.1186/s13014-015-0533-2

Table 1.

Dose objectives used in Auto-Planning for the optimization of head and neck plans

Constraint Priority
Myelon Dmax < 43Gy Medium
Brainstem Dmax < 48Gy Medium
Parotid Mean dose < 22Gy High
Parotid Mean dose < 15Gy Medium
Oral mucosa Mean dose < 20Gy High
Oral mucosa Mean dose < 12Gy Low
Pharynx Dmax < 45Gy Medium
Pharynx Mean dose < 20Gy High
Pharynx Mean dose < 15Gy Medium
Plexus Dmax < 61Gy Medium
Mandibular bones Dmax < 60Gy Medium
Mandibular bones Mean dose < 22Gy Medium
Brain Dmax < 48Gy Medium
Brain Mean dose < 20Gy Medium
Dorsal neck tissue Mean dose < 25Gy Medium